Zum Konfigurator
deen
        

PKA 2

Application
For all electroless nickel plating processes in order to protect the stainless steel. the bath protection processor PKA 2 is used for large and laboratory plants.

Product Description
During electroless nickel plating processes in stainless steel tanks, nickel deposits can build up rapidly, often unexpectedly, inside the bath. Because of the damage this does to the tank’s passive surface, the process bath becomes unsuitable for further production and must be renewed or replaced at great cost. The PKA 2 anodic bath protection processor has been designed to help prevent this. Its dynamic natural potential SCAN® monitors the actual bath potential and automatically calculates and applies the necessary minimal counter-potential. This means a longer life span for your electrolyte, reduced costs, and a higher level of operational safety.

Customer Benefits
A high degree of process safety can be achieved by using the PKA 2 anodic bath protection processor. Its dynamic natural potential SCAN (automatic mode) monitors the actual bath potential and automatically calculates and applies the necessary minimal counter-potential.

11
11

Drawing

11
11

Technical Data

Mains Voltage: 230 V / 50 Hz
(others on request)
Protective Potential: 0…0,9 V (max. 1,0 V) controlled
Protective Current: 0…5,00 A (Option: 10 A)
Protection Grade: IP 54
Dimensions W/D/H: 390 / 160 / 320 [mm] (Standard)
Available as a 19″-plug-in or built into a switch cabinet

Drawing

11
11
11

Interfaces

  • Actual recording: analog
  • Option: Profibus DP/Modbus